ELECTRIC CABLE ONE POLE MAIN SWITCH 1 100A SWITCHBOARD ELECTRICAL
$14.82 inc GSTEnsure safety and control with this single pole 100A main switch for professional electrical installations.
Cable circuit protection systems form the foundation of safe electrical installations, safeguarding cables from overcurrent, short circuits, earth leakage, and overload conditions that can lead to property damage or personal injury. For licensed electricians and contractors managing residential, commercial, and industrial projects, selecting the right protection devices ensures compliance with Australian electrical standards while protecting both the installation and end-users.
At iSupply Electrical, we supply a comprehensive range of cable circuit protection products designed specifically for professional electricians and electrical contractors. Our wholesale pricing and extensive inventory ensure you have reliable access to the protection devices needed to complete projects efficiently and safely.
Our cable protection range encompasses everything required for modern electrical installations. MCBs (Miniature Circuit Breakers) protect cables from damage due to overload or short circuit conditions, offering fast installation with unmatched flexibility for commercial and industrial applications. These devices monitor electrical current and disconnect the supply when unsafe conditions are detected, preventing wire overheating and potential fire hazards.
RCDs (Residual Current Devices) provide critical protection against electric shock by detecting earth leakage currents and immediately disconnecting the power supply. Essential for wet areas, construction sites, and installations where human contact with electrical equipment is likely, RCDs complement MCB protection to deliver comprehensive safety.
RCBOs (Residual Current Breaker with Overcurrent) combine the functionality of both MCBs and RCDs in a single compact device, offering protection against overcurrents, short circuits, and earth leakage simultaneously. This dual protection makes RCBOs ideal for space-constrained switchboards where individual MCB and RCD combinations aren’t practical.
Our range extends to DC Circuit Breakers for renewable energy installations and battery systems, Main Switches for isolating entire installations, Complete Kits for standardized protection solutions, and specialized Asset Protection devices designed to safeguard expensive electrical equipment from damage.
Professional installations require more than just protection devices. Timers and Meters enable precise control and monitoring of electrical systems, essential for energy management and compliance documentation. These devices help contractors deliver value-added services to clients by providing usage data and automated control capabilities that reduce operational costs.
Every cable protection device in our inventory is selected for reliability and compliance with Australian standards. We stock trusted brands that electricians depend on for consistent performance across demanding residential, commercial, and industrial environments. Our wholesale pricing structure ensures competitive project costs without compromising on the quality that licensed professionals require.
Browse our specialized categories including Asset Protection, Complete Kits, DC Circuit Breakers, Main Switch (MCB), MCB, RCBO (MCB/RCD), RCD, and Timers, Meters to find the exact protection solutions your projects demand.
MCBs protect cables and circuits from overcurrent and short circuit conditions by monitoring current flow and disconnecting when safe limits are exceeded. RCDs protect people from electric shock by detecting earth leakage currents (typically as low as 30mA) and immediately cutting power when current flows through an unintended path. Most modern installations require both types of protection – MCBs for circuit protection and RCDs for personal safety.
RCBOs combine overcurrent protection (MCB function) and earth leakage protection (RCD function) in a single device, making them ideal when switchboard space is limited or when individual circuit protection is required. They’re particularly useful in installations where a single RCD would protect multiple circuits – if that RCD trips, all circuits are affected, whereas individual RCBOs allow fault isolation to a single circuit.
Wet areas including bathrooms, kitchens, outdoor sockets, and construction sites require RCD protection due to heightened electric shock risk when water is present. Australian electrical standards mandate 30mA RCD protection for these applications to ensure rapid disconnection if earth leakage occurs. Additional considerations include appropriate IP-rated enclosures and circuit breaker ratings suitable for environmental conditions.
Circuit breaker selection depends on cable size, load characteristics, and installation requirements. The breaker rating must protect the cable from overload while being high enough to handle normal operating currents and inrush currents from motors or transformers. Tripping curves (B, C, D) determine sensitivity – B curves suit resistive loads, C curves handle most general applications, and D curves accommodate high inrush currents from motors or transformers. Licensed electricians should calculate required ratings based on AS/NZS 3000 wiring rules.
DC circuit breakers protect direct current circuits found in solar panel installations, battery storage systems, electric vehicle charging infrastructure, and telecommunications equipment. Unlike AC breakers, DC breakers are specifically designed to safely interrupt DC current, which doesn’t have the natural zero-crossing point that aids AC circuit breaking. Using AC-rated breakers on DC circuits is unsafe and against regulations.
Timers enable automated control of lighting, heating, ventilation, and other electrical systems, reducing energy consumption and providing convenience. Energy meters (kWh meters) measure electrical consumption for billing purposes, compliance documentation, energy audits, and identifying inefficient equipment. Professional contractors use these devices to deliver value-added energy management services to commercial and industrial clients.
Asset protection devices safeguard expensive electrical equipment, machinery, and installations from damage caused by electrical faults, surges, and abnormal operating conditions. These specialized protection devices include surge arrestors, voltage monitoring relays, phase failure relays, and thermal protection devices that prevent costly equipment damage and production downtime.
While technically possible, mixing brands within a switchboard can create compatibility issues, complicate fault-finding, and may void warranties or compliance certifications. Professional electricians typically standardize on a single manufacturer’s system within each switchboard to ensure proper coordination between protection devices and maintain clear documentation for future maintenance.
Showing 97–112 of 140 results

Ensure safety and control with this single pole 100A main switch for professional electrical installations.

SINGLE POLE 80AMP DIN RAIL MAIN SWITCH Colour: White (80a) Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by to pickup an item so you can save on your shipping or have a…

Flush/Surface Mount! This package include 2 pole RCBOs which means if there is an overload or earth leakage, only one circuit trips and not other circuits ( keeping vital circuits running with no interruption ) Dimension: 34.5cm (W) x 30cm (L) x 9cm (D) 1 x 24 Way Wall Mount Switch Board 2 x 80…

Switchboard Combination for 12 pole switchboard 1x 12 pole Surface Mount Distribution Board 1 x 12 Way Wall Mount Switch Board 1 x 80 amp Main breaker / Isolator 1 x 63 amp 2 Pole RCD 6 KA 3 x 20 amp circuit breaker— Stove / Oven – Hot water / Aircon 3 x 16…

Switchboard Combination for 8 pole switchboard 1x 8 pole Surface Mount Distribution Board 1 x 8 Way Wall Mount Switch Board 1 x 80 amp Main breaker / Isolator 1 x 20 amp circuit breaker— Stove / Oven – Hot water / Aircon 3 x 16 amp circuit breaker – Powerpoints 3 x 10 amp…

Switchboard Combination for 8 pole switchboard 1x 8 pole Surface Mount Distribution Board 1 x 63 amp Main breaker / Isolator 3 x 16 amp circuit breaker – Powerpoints 2 x 10 amp circuit breaker – Light Switchboard dimensions: 284mm x 200mm x 90mm Distribution board, neutral link, and marking stickers Condition: Brand new, original packaging…

Compact, reliable Mini RCBO 10A – 1Pole, 3kA rated, perfect for fast, safe electrical installations.

Mini RCBO 16Amps – 1Pole 3kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 10Amps – 1Pole 4.5kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 20Amps – 1Pole 3kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 10Amps – 1Pole 3kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 10Amps – 1Pole 4.5kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 10Amps – 1Pole 4.5kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 16Amps – 1Pole 4.5kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 10Amps – 1Pole 4.5kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 20Amps – 1Pole 4.5kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 10Amps – 1Pole 4.5kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 10Amps – 1Pole 6kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 16Amps – 1Pole 6kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 16Amps – 1Pole 6kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 16Amps – 1Pole 6kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 20Amps – 1Pole 6kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 16Amps – 1Pole 6kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote We are a fully functioning store, if your local, you can drop by…

Mini RCBO 32 Amps – 1Pole 6kA rating Colour: White (available in 10A, 16A, 20A,) Specifications: Mini RCBO 16Amps – 1Pole 6kA 30ma 240v rating Condition: Brand new, original packaging Additional Notes: Australian Standards Approved Need bulk quantity? Contact us for a quote
Cable circuit protection systems form the foundation of safe electrical installations, safeguarding cables from overcurrent, short circuits, earth leakage, and overload conditions that can lead to property damage or personal injury. For licensed electricians and contractors managing residential, commercial, and industrial projects, selecting the right protection devices ensures compliance with Australian electrical standards while protecting both the installation and end-users.
At iSupply Electrical, we supply a comprehensive range of cable circuit protection products designed specifically for professional electricians and electrical contractors. Our wholesale pricing and extensive inventory ensure you have reliable access to the protection devices needed to complete projects efficiently and safely.
Our cable protection range encompasses everything required for modern electrical installations. MCBs (Miniature Circuit Breakers) protect cables from damage due to overload or short circuit conditions, offering fast installation with unmatched flexibility for commercial and industrial applications. These devices monitor electrical current and disconnect the supply when unsafe conditions are detected, preventing wire overheating and potential fire hazards.
RCDs (Residual Current Devices) provide critical protection against electric shock by detecting earth leakage currents and immediately disconnecting the power supply. Essential for wet areas, construction sites, and installations where human contact with electrical equipment is likely, RCDs complement MCB protection to deliver comprehensive safety.
RCBOs (Residual Current Breaker with Overcurrent) combine the functionality of both MCBs and RCDs in a single compact device, offering protection against overcurrents, short circuits, and earth leakage simultaneously. This dual protection makes RCBOs ideal for space-constrained switchboards where individual MCB and RCD combinations aren’t practical.
Our range extends to DC Circuit Breakers for renewable energy installations and battery systems, Main Switches for isolating entire installations, Complete Kits for standardized protection solutions, and specialized Asset Protection devices designed to safeguard expensive electrical equipment from damage.
Professional installations require more than just protection devices. Timers and Meters enable precise control and monitoring of electrical systems, essential for energy management and compliance documentation. These devices help contractors deliver value-added services to clients by providing usage data and automated control capabilities that reduce operational costs.
Every cable protection device in our inventory is selected for reliability and compliance with Australian standards. We stock trusted brands that electricians depend on for consistent performance across demanding residential, commercial, and industrial environments. Our wholesale pricing structure ensures competitive project costs without compromising on the quality that licensed professionals require.
Browse our specialized categories including Asset Protection, Complete Kits, DC Circuit Breakers, Main Switch (MCB), MCB, RCBO (MCB/RCD), RCD, and Timers, Meters to find the exact protection solutions your projects demand.
MCBs protect cables and circuits from overcurrent and short circuit conditions by monitoring current flow and disconnecting when safe limits are exceeded. RCDs protect people from electric shock by detecting earth leakage currents (typically as low as 30mA) and immediately cutting power when current flows through an unintended path. Most modern installations require both types of protection – MCBs for circuit protection and RCDs for personal safety.
RCBOs combine overcurrent protection (MCB function) and earth leakage protection (RCD function) in a single device, making them ideal when switchboard space is limited or when individual circuit protection is required. They’re particularly useful in installations where a single RCD would protect multiple circuits – if that RCD trips, all circuits are affected, whereas individual RCBOs allow fault isolation to a single circuit.
Wet areas including bathrooms, kitchens, outdoor sockets, and construction sites require RCD protection due to heightened electric shock risk when water is present. Australian electrical standards mandate 30mA RCD protection for these applications to ensure rapid disconnection if earth leakage occurs. Additional considerations include appropriate IP-rated enclosures and circuit breaker ratings suitable for environmental conditions.
Circuit breaker selection depends on cable size, load characteristics, and installation requirements. The breaker rating must protect the cable from overload while being high enough to handle normal operating currents and inrush currents from motors or transformers. Tripping curves (B, C, D) determine sensitivity – B curves suit resistive loads, C curves handle most general applications, and D curves accommodate high inrush currents from motors or transformers. Licensed electricians should calculate required ratings based on AS/NZS 3000 wiring rules.
DC circuit breakers protect direct current circuits found in solar panel installations, battery storage systems, electric vehicle charging infrastructure, and telecommunications equipment. Unlike AC breakers, DC breakers are specifically designed to safely interrupt DC current, which doesn’t have the natural zero-crossing point that aids AC circuit breaking. Using AC-rated breakers on DC circuits is unsafe and against regulations.
Timers enable automated control of lighting, heating, ventilation, and other electrical systems, reducing energy consumption and providing convenience. Energy meters (kWh meters) measure electrical consumption for billing purposes, compliance documentation, energy audits, and identifying inefficient equipment. Professional contractors use these devices to deliver value-added energy management services to commercial and industrial clients.
Asset protection devices safeguard expensive electrical equipment, machinery, and installations from damage caused by electrical faults, surges, and abnormal operating conditions. These specialized protection devices include surge arrestors, voltage monitoring relays, phase failure relays, and thermal protection devices that prevent costly equipment damage and production downtime.
While technically possible, mixing brands within a switchboard can create compatibility issues, complicate fault-finding, and may void warranties or compliance certifications. Professional electricians typically standardize on a single manufacturer’s system within each switchboard to ensure proper coordination between protection devices and maintain clear documentation for future maintenance.
Looks like you haven't made a choice yet.